Frequency Monitor

Frequency Monitor

Brand: MRS Electronics

Category: Frequency Monitors

Request a Quote

The Fre­quency Mon­i­tor is used to switch loads on/off when the input sig­nal fre­quency ex­ceeds/drops below a de­fined thresh­old fre­quency.

Function

The fre­quency mon­i­tor mea­sures the input sig­nal fre­quency ap­plied to ter­mi­nal 15 and en­er­gizes/de-en­er­gizes the out­put when the sig­nal fre­quency ex­ceeds/drops below the de­fined thresh­old fre­quency. The thresh­old fre­quency can be se­lected from the 10 - 1.000 Hz fre­quency range. In ad­di­tion, com­bi­na­tions in­clud­ing cus­tom delay times are pos­si­ble.

Please refer to the chap­ter hous­ing and base plates for ad­di­tional hous­ing op­tions.

Application Examples

Application Examples
Au­to­matic start
RPM mea­sure­ment
Flow rate mon­i­tor­ing

Technical Data

Product Name   Value
Op­er­at­ing tem­per­ture   -40 °C to 85 °C
Thresh­old fre­quency   Per cus­tomer re­quest
Con­tin­u­ous cur­rent limit   10A/15 A (no/nc)
Switch­ing time ac­cu­racy   +/- 1 ms
En­vi­ron­men­tal pro­tec­tion   IP53
Qui­es­cent cur­rent   250 µA
EMC   2006/96/EG DIN 40839
e1 ap­proval num­ber   03 3218

Product Details

Product Name   Model   Features   Housing   Order No.
Fre­quency mon­i­tor 12 V relay   A   xxx = fre­quency in Hz   S1/G2/E   1.?026.?111.?xxxE
Fre­quency mon­i­tor 24 V relay   A   xxx = fre­quency in Hz   S1/G2/E   1.?026.?211.?xxxE
Fre­quency mon­i­tor 12 V relay   B   xxx = fre­quency in Hz   S2/G2/Y   1.?026.?112.?xxxE
Fre­quency mon­i­tor 24 V relay   B   xxx = fre­quency in Hz   S2/G2/Y   1.?026.?212.?xxxE
Fre­quency mon­i­tor 19 - 30 V HSD   A   xxx = fre­quency in Hz   S3/G2/E   1.?026.?311.?xxxE

Accessories

Product Name   Order No.
Pro­gram­ming tool MRS Re­al­izer I   1.?100.?000.?01
Flat pin socket   1.?017.?002.?00
FAS­TON ter­mi­nal 6.3 mm 1.5-2.5 mm2   103064
FAS­TON ter­mi­nal 6.3 mm 1 mm2   102355
FAS­TON ter­mi­nal 2.8 mm 0.5-1.0 mm2   105292
Hous­ing bracket   1.?017.?080.?00