Time Relay Switch On Delay Adjustable
Brand: MRS Electronics
Category: Time Relays
Request a QuoteThe Time Relay Switch On Delay Adjustable allows the user to adjust the switch-on delay time via potentiometer setting within one of the five available standard delay time intervals. Custom delay time intervals are available on request. Please specify the desired switch-on delay time interval in the purchase order.
Diagram S1, S2: The supply voltage is connected to terminal 30/87z. When a signal voltage is applied to terminal 15 (trigger) the relay output will energize after the preset switch-on delay time. When the signal voltage is removed from terminal 15 the relay output will switch off immediately.
Diagram S2: Output contacts are electrically separated from input contacts which allows for relay combination solutions.
Please refer to the chapter housing and base plates for additional housing options.
Application Examples |
---|
Air conditioning switch-on delay |
Compressor switch-on delay |
Product Name | Value | |
---|---|---|
Operating temperature | -40 °C to 85 °C | |
Continuous current limit | 10A/15 A (o/c) | |
Time delay accuracy | +/- 1 % | |
Environmental protection | IP53 (with potentiometer cover) | |
Quiescent current | 250 µA | |
e1 approval number | 03 3218 |
Product Name | Model | Housing | Order No. | |||
---|---|---|---|---|---|---|
Time relay adjust. switch-on 12V | A | S1/G2/E | 1.?022.?112.?XXE | |||
Time relay adjust. switch-on 24V | A | S1/G2/E | 1.?022.?212.?XXE | |||
Time relay adjust. switch-on 12V | C | S2/G2/E | 1.?022.?110.?XXE | |||
Time relay adjust. switch-on 24V | C | S2/G2/E | 1.?022.?210.?XXE |
Product Name | Order No. | |
---|---|---|
Programming tool MRS Realizer I | 1.?100.?000.?01 | |
Flat pin socket | 1.?017.?002.?00 | |
FASTON terminal 6.3mm 1.5-2.5 mm2 | 103064 | |
FASTON terminal 6.3 mm 1 mm2 | 102355 | |
FASTON terminal 2.8 mm 0.5-1.0 mm2 | 105292 | |
Housing bracket | 1.?017.?080.?00 |
Standard Interval options | Delay time range |
---|---|
XX = 01: | 0.5 - 5 sec. |
XX = 02: | 1 - 30 sec. |
XX = 03: | 0.5 - 60 sec. |
XX = 04: | 30 - 900 sec. |
XX = 05: | 0.5 - 4000 sec. |