Time Relay Switch On Delay Adjustable
The Time Relay Switch On Delay Adjustable allows the user to adjust the switch-on delay time via potentiometer setting within one of the five available standard delay time intervals. Custom delay time intervals are available on request. Please specify the desired switch-on delay time interval in the purchase order.
Function
Diagram S1, S2: The supply voltage is connected to terminal 30/87z. When a signal voltage is applied to terminal 15 (trigger) the relay output will energize after the preset switch-on delay time. When the signal voltage is removed from terminal 15 the relay output will switch off immediately.
Diagram S2: Output contacts are electrically separated from input contacts which allows for relay combination solutions.
Please refer to the chapter housing and base plates for additional housing options.
Application Examples
Application Examples |
---|
Air conditioning switch-on delay |
Compressor switch-on delay |
Technical data
Product Name | | Value |
---|
Operating temperature | | -40 °C to 85 °C |
Continuous current limit | | 10A/15 A (o/c) |
Time delay accuracy | | +/- 1 % |
Environmental protection | | IP53 (with potentiometer cover) |
Quiescent current | | 250 µA |
e1 approval number | | 03 3218 |
Function Diagram
Design
Connection diagram
Product Details
Product Name | | Model | | Housing | | Order No. |
---|
Time relay adjust. switch-on 12V | | A | | S1/G2/E | | 1.022.112.XXE |
Time relay adjust. switch-on 24V | | A | | S1/G2/E | | 1.022.212.XXE |
Time relay adjust. switch-on 12V | | C | | S2/G2/E | | 1.022.110.XXE |
Time relay adjust. switch-on 24V | | C | | S2/G2/E | | 1.022.210.XXE |
Accessories
Product Name | | Order No. |
---|
Programming tool MRS Realizer I | | 1.100.000.01 |
Flat pin socket | | 1.017.002.00 |
FASTON terminal 6.3mm 1.5-2.5 mm2 | | 103064 |
FASTON terminal 6.3 mm 1 mm2 | | 102355 |
FASTON terminal 2.8 mm 0.5-1.0 mm2 | | 105292 |
Housing bracket | | 1.017.080.00 |
Function Table
Standard Interval options | Delay time range |
---|
XX = 01: | 0.5 - 5 sec. |
XX = 02: | 1 - 30 sec. |
XX = 03: | 0.5 - 60 sec. |
XX = 04: | 30 - 900 sec. |
XX = 05: | 0.5 - 4000 sec. |