Time Relay Switch On Delay Adjustable

The Time Relay Switch On Delay Ad­justable al­lows the user to ad­just the switch-on delay time via po­ten­tiome­ter set­ting within one of the five avail­able stan­dard delay time in­ter­vals. Cus­tom delay time in­ter­vals are avail­able on re­quest. Please spec­ify the de­sired switch-on delay time in­ter­val in the pur­chase order.

 

Function

Di­a­gram S1, S2: The sup­ply volt­age is con­nected to ter­mi­nal 30/87z. When a sig­nal volt­age is ap­plied to ter­mi­nal 15 (trig­ger) the relay out­put will en­er­gize after the pre­set switch-on delay time. When the sig­nal volt­age is re­moved from ter­mi­nal 15 the relay out­put will switch off im­me­di­ately.

Di­a­gram S2: Out­put con­tacts are elec­tri­cally sep­a­rated from input con­tacts which al­lows for relay com­bi­na­tion so­lu­tions.
Please refer to the chap­ter hous­ing and base plates for ad­di­tional hous­ing op­tions.

Application Examples

Application Examples
Air con­di­tion­ing switch-on delay
Com­pres­sor switch-on delay

Technical data

Product Name Value
Op­er­at­ing tem­per­a­ture -40 °C to 85 °C
Con­tin­u­ous cur­rent limit 10A/15 A (o/c)
Time delay ac­cu­racy +/- 1 %
En­vi­ron­men­tal pro­tec­tion IP53 (with po­ten­tiome­ter cover)
Qui­es­cent cur­rent 250 µA
e1 ap­proval num­ber 03 3218

Function Diagram

Design

Connection diagram

Product Details

Product Name Model Housing Order No.
Time relay ad­just. switch-on 12V A S1/G2/E 1.​022.​112.​XXE
Time relay ad­just. switch-on 24V A S1/G2/E 1.​022.​212.​XXE
Time relay ad­just. switch-on 12V C S2/G2/E 1.​022.​110.​XXE
Time relay ad­just. switch-on 24V C S2/G2/E 1.​022.​210.​XXE

Accessories

Product Name Order No.
Pro­gram­ming tool MRS Re­al­izer I 1.​100.​000.​01
Flat pin socket 1.​017.​002.​00
FAS­TON ter­mi­nal 6.3mm 1.5-2.5 mm2 103064
FAS­TON ter­mi­nal 6.3 mm 1 mm2 102355
FAS­TON ter­mi­nal 2.8 mm 0.5-1.0 mm2 105292
Hous­ing bracket 1.​017.​080.​00

Function Table

Standard Interval optionsDelay time range
XX = 01:0.5 - 5 sec.
XX = 02:1 - 30 sec.
XX = 03:0.5 - 60 sec.
XX = 04:30 - 900 sec.
XX = 05:0.5 - 4000 sec.