Time Relay Switch Off Delay Compact

The Time Relay Switch Off Delay Com­pact is de­signed for time-de­layed switch­ing off of loads. Please spec­ify the re­quired switch-off delay time in the order.

 

Function

Di­a­grams S1, S2: The sup­ply volt­age is con­nected to ter­mi­nals 30/87z. When a sig­nal volt­age is ap­plied to ter­mi­nal 15 (trig­ger) the relay out­put will en­er­gize im­me­di­ately. When the sig­nal volt­age is re­moved from ter­mi­nal 15 the relay out­put will re­main en­er­gized until the end of the pre­set switch-off delay time.
Di­a­gram S2: Out­put con­tacts are elec­tri­cally sep­a­rated from input con­tacts which al­lows for relay com­bi­na­tion so­lu­tions. In this con­fig­u­ra­tion the relay con­tact is po­ten­tial-free and can be used to switch al­ter­nat­ing volt­ages.
Please refer to the chap­ter hous­ing and base plates for ad­di­tional hous­ing op­tions.

Application Examples

Application Examples
De­frost
De­layed light­ing switch-off

Technical data

Product Name Value
Hous­ing di­men­sions 30 x 30 x 30 mm
Op­er­at­ing tem­per­a­ture -40 °C to 85 °C
Switch­ing volt­age limit 12 V / 24 V DC
Qui­es­cent cur­rent 1 mA
Delay time Cus­tom de­fined
En­vi­ron­men­tal pro­tec­tion IP53
IP65 On re­quest
E1 ap­proval num­ber 04 7281
max. switch­ing volt­age/switch­ing cur­rent/con­tin­u­ous cur­rent/switch-on cur­rent see datasheet Hongfa HFKP/012-1Z3T (12 V) or HFKP/024-1Z3T (24 V)

Function Diagram

Design

Connection diagram

Product Details

Product Name Model Housing Order No.
Time relay M1 switch-off 12V A S1/G1/E 1.​003.​181.​00E
Time relay M1 switch-off 24V A S1/G1/E 1.​003.​281.​00E
Time relay M1 switch-off 12V B S2/G1/Y 1.​003.​182.​00E
Time relay M1 switch-off 24V B S2/G1/Y 1.​003.​282.​00E

Accessories

Product Name Order No.
Pro­gram­ming tool MRS Re­al­izer I 1.​100.​000.​01
Flat pin socket 1.​017.​002.​00
FAS­TON ter­mi­nal 6.3 mm 1.5-2.5 mm2 103064
FAS­TON ter­mi­nal 6.3 mm 1 mm2 102355
FAS­TON ter­mi­nal 2.8 mm 0.5-1.0 mm2 105292